Service Pack 12 for NeuroCheck 5.1

Windows 7 Logo Even after the release of version 6.0, the extremely successful version 5.1 of our image processing software NeuroCheck continues to be supported. With Service Pack 12, NeuroCheck 5.1 fully supports the new Microsoft® operating system Windows® 7 and also accelerates several frequently used image processing algorithms and automatic check execution. After extensive testing, Tech Support can give the official go-ahead for using software version 5.1 with the new Microsoft operating system Windows® 7. If necessary, please ask us for a current list of all successfully tested hardware components at support@fsinet.com.


Performance Optimization By careful optimization, the execution speed of numerous image processing algorithms has been significantly increased. In addition, the performance in automatic mode has been improved as well. Those applications making heavy use of system and memory resources now run significantly faster.




Name Version Date File size
NeuroCheck 5.1 Service Pack 12 5.1.1091 1-20-2010 10 MB
NCG Series GigE camera driver 5.1.2 1-20-2010 2 MB
Baumer FWX NC Edition & NCF Series IEEE 1394 camera driver 5.1.3047.0 1-20-2010 4 MB

Only for use by current users of Version 5.1. If you would like to upgrade your system from version 5.0 or earlier please contact FSI Machine Vision.

Important Notes

This service pack contains new features, enhancements and bug-fixes. For details please contact our technical support.

The file format for check routines remains unchanged since SP7. Due to the new features in SP7, the CHR file format has changed in comparison to previous releases. Old check routine files can be loaded as usual, but check routines created with SP7 or higher cannot be read by previous NeuroCheck versions.

Due to compatibility reasons, the new camera drivers are not included in this Service-Pack. The IEEE 1394 camera driver of the Baumer FWX NC Edition and NCF series is available as a separate download on this page. If you currently are using a Basler BCam IEEE 1394 camera or a mvTITAN frame grabber board then please contact our Technical Support for the special compatibility notes.


Installation

Most of the files are self-extracting zip archive packed with WinZip Self-Extractor. Unpack the archives to NeuroCheck's installation directory, if no other location is stated. Necessary sub-directories will be created automatically.

  • Copy the service pack into an arbitrary directory on your NeuroCheck system.
  • On Windows XP, double-click the service pack.
    On Windows Vista and Windows 7 operating system, please right-click and select "Run as Administrator".
  • In the appearing dialog, configure the installation directory of NeuroCheck 5.1.
  • Click "Unzip" to overwrite the existing files of your NeuroCheck installation with newer versions.
  • At the end of the installation file History.txt will be opened to inform you in detail about the changes in this service pack.

Please note that a subsequent repair run of the original setup for NeuroCheck 5.1 will replace most of the updated files with their original versions, requiring a re-run of the service pack.